HCD-GP6V
RFDC signal waveform
Checking Location: BD board (Conductor side)
RFAC Level Check
Connection:
Procedure:
1.
1.
Connect an oscilloscope to test point TP6 (RFAC) and TP7
(VC) on the BD board.
(VC) on the BD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Confirm that oscilloscope waveform is clear and check RFAC
signal level is correct or not.
signal level is correct or not.
Note:
A clear RFAC signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
RFAC signal waveform
Checking Location: BD board (Conductor side)
CD SECTION
Note:
1. CD Block is basically designed to operate without adjustment. There-
fore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
3. Use an oscilloscope with more than 10M
Ω impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-curve Check
Connection:
Procedure:
1.
1.
Connect an oscilloscope to test point TP4 (FE) and TP7 (VC)
on the BD board.
on the BD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in and turned power switch on again
and actuate the focus search. (actuate the focus search when
disc table is moving in and out)
and actuate the focus search. (actuate the focus search when
disc table is moving in and out)
4.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 2 ± 1
Vp-p.
between A and B. And confirm peak to peak level within 2 ± 1
Vp-p.
S-curve waveform
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Checking Location: BD board (Conductor side)
RFDC Level Check
Connection:
Procedure:
1.
1.
Connect an oscilloscope to test point TP6 (RFDC) and TP7
(VC) on the BD board.
(VC) on the BD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Confirm that oscilloscope waveform is clear and check RFDC
signal level is correct or not.
signal level is correct or not.
Note:
A clear RFDC signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
+
–
–
BD board
TP4 (FE)
TP7 (VC)
oscilloscope
A
B
symmetry
within 2
±
1 Vp-p
+
–
–
BD board
TP6 (RFDC)
TP7 (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
TIME/DIV: 500 ns
level: 0.7
±
0.2 Vp-p
+
–
–
BD board
TP6 (RFAC)
TP7 (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
TIME/DIV: 500 ns
level: 1.0
±
0.4 Vp-p