Read Sony CMT-EP50LIV / HCD-EP50LIV Service Manual online
13
HCD-EP50LIV
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
T8
530 kHz
1.3
±
0.1 V
Confirmation
1,710 kHz
7.8
±
0.5 V
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
T6
603 kHz
TC1
1,404 kHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L901
87.5 MHz
2.4
±
0.1 V
Confirmation
108 MHz
6.8
±
0.5 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L902
90.1 MHz
TC901
106.1 MHz
Adjustment Location: MAIN board (See page 14)
TUNER SECTION
0 dB=1
µ
V
[AM]
Setting:
Function
Function
: TUNER
Band switch : AM
[FM]
Setting:
Function
Function
: TUNER
Band switch : FM
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
done by the trimmer capacitors.
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
Output level: as low as possible
modulation by
400 Hz signal
Output level: as low as possible
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
+
–
–
level meter
set
32
Ω
MAIN board
SPEAKER terminal (CN17)
SPEAKER terminal (CN17)
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: as low as possible
deviation by 400 Hz
signal
Output level: as low as possible
+
–
–
level meter
set
32
Ω
0.01
µ
F
MAIN board
FM ANT
FM ANT
MAIN board
SPEAKER terminal (CN17)
SPEAKER terminal (CN17)
digital voltmeter
100 k
Ω
MAIN board
TP (FM VT)
TP (AM VT)
TP (AM VT)