Read Sony CMT-EP505 / HCD-EP505 Service Manual online
35
HCD-EP505
Pin No.
Pin Name
I/O
Description
78
VSS
—
Ground terminal
79
X2
O
Main system clock output terminal (4.194304 MHz)
80
X1
I
Main system clock input terminal (4.194304 MHz)
81
VDD
—
Power supply terminal
82
XT1
I
Sub system clock input terminal (32.768 kHz) Not used
83
XT2
O
Sub system clock output terminal (32.768 kHz) Not used
84
RESET
I
System reset signal input from the reset signal generator “L”: reset
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
85
REMOTE
I
Remote control signal input from the remote control receiver
86
PWRFAIL
I
Power failure detection signal input terminal “L”: power failure, “H”: power on
87
RDSCLK
I
Serial data transfer clock signal input from the RDS decoder
(Used for the AEP, UK models)
(Used for the AEP, UK models)
88
CDCLK
I
Serial data transfer clock signal input from the CD block
89
SENSORB
I
Tape sensor input terminal Not used
90
SENSORA
I
Tape play/rec detect sensor input terminal “L” input when the tape play/rec detect
91
CD DOOR SW
I
CD lid open/close detect switch (SW300) input terminal “L”: CD lid is closed
92
CD-EN
O
CD power on/off control signal output terminal
93
SOL
O
Trigger plunger drive signal output terminal “H”: trigger plunger on
94
TU-EN
O
Tuner power on/off control signal output terminal
95
MOTOR-ON
O
Motor control signal output terminal
96
AMS
I
Whether a music is present or not from AMS is detected at auto music sensor
“L”: music is not present, “H”: music is present
“L”: music is not present, “H”: music is present
97
ENCODERA
I
Jog dial pulse input from the rotary encoder (VOLUME) (A phase input)
98
ENCODERB
I
Jog dial pulse input from the rotary encoder (VOLUME) (B phase input)
99
AVSS
—
Ground terminal
100
KEY1
I
Key input terminal (A/D input)
Ver 1.1