HCD-EP505
NOTES ON HANDLING THE OPTICAL PICK-UP
BLOCK OR BASE UNIT
BLOCK OR BASE UNIT
The laser diode in the optical pick-up block may suffer electro-
static break-down because of the potential difference generated
by the charged electrostatic load, etc. on clothing and the human
body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
static break-down because of the potential difference generated
by the charged electrostatic load, etc. on clothing and the human
body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
NOTES ON LASER DIODE EMISSION CHECK
The laser beam on this model is concentrated so as to be focused
on the disc reflective surface by the objective lens in the optical
pick-up block. Therefore, when checking the laser diode emis-
sion, observe from more than 30 cm away from the objective lens.
on the disc reflective surface by the objective lens in the optical
pick-up block. Therefore, when checking the laser diode emis-
sion, observe from more than 30 cm away from the objective lens.
LASER DIODE AND FOCUS SEARCH OPERATION
CHECK
CHECK
1. Press the
I/1
button to the power ON with no disc inserted
and press the
[CD]
button.
2. Open the lid for CD.
3. Turn on SW300 as following figure.
4. Confirm the laser diode emission while observing the object-
3. Turn on SW300 as following figure.
4. Confirm the laser diode emission while observing the object-
ing lens. When there is no emission, Auto Power Control cir-
cuit or Optical Pick-up is broken.
Objective lens moves up and down five times for the focus
search.
cuit or Optical Pick-up is broken.
Objective lens moves up and down five times for the focus
search.
SECTION 1
SERVICING NOTES
SW300
Ver 1.1
• MODEL IDENTIFICATION
– Bottom View –
– Bottom View –
Power Voltage Indication
Power Voltage
Indication
AC: 120 V 60 Hz 35 W
AC: 220 – 230 V - 50/60 Hz 40 W
AC: 230 V - 50/60 Hz 40 W
Model
US and Canadian
models
models
Argentina model
Other models