CMT-EP505, HCD-EP505 - Sony Audio Service Manual (repair manual). Page 11

Read Sony CMT-EP505 / HCD-EP505 Service Manual online

11
HCD-EP505
SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
Tape Speed Adjustment
Setting:
Function: TAPE
Procedure:
1. Playback WS-48B (tape center) in the FWD state.
2. Adjsut the volume in CAPSTAN/REEL motor so that the fre-
quency counter reading becomes 3,000 Hz.
Specified Value: 2,910 to 3,090 Hz
3. Confirm that the frequency at the beginning and that at the
end of tape winding are between 2,955 to 3,045 Hz.
Adjustment Location:
PRECAUTION
1. Setting
MEGA BASS switch : OFF
TAPE  DECK  SECTION
0 dB=0.775 V
Test tape
Type
Signal
Used for
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
frequency counter
test tape 
WS-48B
(3 kHz, 0 dB)
set
MAIN board
SPEAKER terminal (CN503)
+
47 k
CAPSTAN/REEL
motor
Tape Speed
Adjustment
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 100 g
(more than 3.53 oz)
• Tape Tension  Measurement
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head magnetizer close to the erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
• Torque Measurement
Mode
Torque Meter
Meter Reading
2.95 – 6.86 mN•m
FWD
CQ-102C
(30 – 70 g•cm)
(0.42 – 0.97 oz•inch)
0.15 – 5.39 mN•m
FWD
CQ-102C
(1.5 – 5.5 g•cm)
Back Tension
(0.021 – 0.076 oz•inch)
more than 5.89 mN•m
FF
CQ-201B
(more than 60 g•cm)
(more than 0.83 oz•inch)
more than 5.89 mN•m
REW
CQ-201B
(more than 60 g•cm)
(more than 0.83 oz•inch)
Sample Value of  Wow and Flutter: 0.3% or less W. RMS (JIS)
(WS-48B)
Page of 50
Display

Click on the first or last page to see other CMT-EP505 / HCD-EP505 service manuals if exist.