CMT-EP50, HCD-EP50 - Sony Audio Service Manual (repair manual). Page 12

Read Sony CMT-EP50 / HCD-EP50 Service Manual online

12
HCD-EP50
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode: Playback (FWD)
4. Repeat step 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
parts adjusted.
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
test tape 
P-4-A100
(10 kHz, –10 dB)
L-CH
R-CH
MAIN board
SPEAKER terminal (CN17)
oscilloscope
V
H
+ +
screen pattern
in phase
good
wrong
45 
°
90 
°
135 
°
180 
°
47 k
47 k
set
Record/Playback Head Azimuth Adjustment
Procedure:
1. Mode: Playback (FWD)
level meter
test tape 
P-4-A100
(10 kHz, –10 dB)
set
MAIN board
SPEAKER terminal (CN17)
47 k
+
Adjustment Location: Record/Playback Head.
Note: Refer to “3-7. CASSETTE LID” (see page 10)