CMT-EH15, HCD-EH15 - Sony Audio Service Manual (repair manual). Page 11

Read Sony CMT-EH15 / HCD-EH15 Service Manual online

HCD-EH15
11
Adjustment Location: Record/Playback/Erase Head
Note:  Remove the cassette lid before this adjustment.
 
Refer to “DISASSEMBLY” (page 6)
TUNER SECTION      0 dB=1 μV
[AM]
Setting:
Function: TUNER
Band: AM
AM RF signal 
generator
30% amplitude 
modulation by 
400 Hz signal
60 cm
set
loop antenna A
loop antenna B
[FM]
Setting:
Function: TUNER
Band: FM
FM RF signal
generator
1 kHz frequency
deviation by FM 75 kHz
signal
Output level: 
as low as possible
+
level meter
MAIN board
JW148
(GND)
MAIN board
JW403
(TUNER OUT L-ch)
set
MAIN board
CNP802 pin 
MAIN board
CNP802 pin 
digital voltmeter
JW821 (VT)
JW805 (GND)
10 k
Ω
MAIN board
•  Repeat the procedures in each adjustment several times, and 
the  tracking adjustments should be fi nally done by the trimmer 
capacitors.
•  Remove FM antenna in FM adjustment.
( ): AEP, Russian and UK models
AM  VT  VOLTAGE ADJUSTMENT
Adjustment Part Frequency Display Reading on Digital Voltmeter
L852
530 (531) kHz
1.5 ± 0.1 V
Confi rmation
1710 (1602) kHz
8.0 (7.2) ± 0.5 V
( ): AEP, Russian and UK models
AM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L851
530 (531) kHz
FM  VT  VOLTAGE ADJUSTMENT
Adjustment Part Frequency Display Reading on Digital Voltmeter
L805
87.5 MHz
1.75 ± 0.1 V
Confi rmation
108 MHz
6.2 ± 0.5 V
FM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L804
98 MHz
FM  DETECTOR  ADJUSTMENT
Setting:
Function: TUNER
BAND button: FM
set
MAIN board
JW403
(TUNER OUT L-ch)
MAIN board
JW148 (GND)
Carrier frequency : 98 MHz
Modulation
: deviation by
FM 75 kHZ
Output level
: 60 dB
FM RF Signal 
generator
1.  Tune the set to 98 MHz.
2.  Adjust L806 so that modulation distortion may become the 
best in the vicinity of the maximum value where the tuner out 
level becomes 
15 dBs or more.
Ver. 1.2
Page of 41
Display

Click on the first or last page to see other CMT-EH15 / HCD-EH15 service manuals if exist.