12
HCD-E301
Adjustment Location and Connecting Points
– MAIN BOARD (Component Side) –
L104 FM Frequency
Coverage Adjustment
T102
AM Frequency Coverage Adjustment
TC102 
}
AM Tracking
L110
Adjustment
L103
FM Tracking
TC101 
}
Adjustment
– MAIN BOARD (Conductor Side) –
TP10
(FM VT)
TP11
(AM VT)
IC101
AM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
Confirmation
531 kHz
1.5 
±
 0.2 V
T102
1,602 kHz
7.3 
±
 0.3 V
AM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L110
603 kHz
TC102
1,404 kHz
FM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L104
87.6 MHz
2.1 
±
 0.2 V
Confirmation
108 MHz
7.0 
±
 0.4 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L103
89.9 MHz
TC101
105.9 MHz
TUNER  SECTION
0 dB=1 
µ
V
[AM]
Setting:
Function
: TUNER
Band switch : AM
[FM]
Setting:
Function
: TUNER
Band switch : FM
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
32 
HEADPHONE board
PHONES jack (JK401)
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: as low as possible
+
level meter
set
32 
0.01 
µ
F
MAIN board
FM ANT
HEADPHONE board
PHONES jack (JK401)
digital voltmeter
100 k
MAIN board
TP10 (FM VT)
TP11 (AM VT)
Page of 34