The laser diode in the optical pick-up block may suffer electrostatic
break-down because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the human body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
NOTES  ON  LASER  DIODE  EMISSION  CHECK
The laser beam on this model is concentrated so as to be focused on
the disc reflective surface by the objective lens in the optical pick-
up block. Therefore, when checking the laser diode emission,
observe from more than 30 cm away from the objective lens.
NOTES  ON  HANDLING  THE  OPTICAL  PICK-UP
BLOCK  OR  BASE  UNIT
MODEL  IDENTIFICATION
– Back Panel –
Power requirement 
indication
• Abbreviation
AUS
: Australian model
CND
: Canadian model
E3
: 240 V AC Area in E model
E51
: Chilean and Peruvian models
KR
: Korean model
RU
: Russian model
SP
: Singapore model
TH
: Thai model
•  SERVICE POSITION OF THE TAPE CASSETTE MECHANISM DECK
DISC TRAY  LOCK
The disc tray lock function for the antitheft of an demonstration
disc in the store is equipped.
Procedure :
1. Press the  ?/1  button to turn the set ON.
2. Press the  DVD u button to select “DVD”
3. Set disc on the tray, press the  x  button and the  Z  button
simultaneously for five seconds.
4. The message “LOCKED” is displayed the tray is locked.
5. To release from this mode, press the  x  button and the  Z
button simultaneously for five seconds again.
6. The message “UNLOCKED” is displayed and the tray is
unlocked.
Note:
When “LOCKED” is displayed, the slot lock is not released by
turning power on/off with the  ?/1  button.
Model
Power Voltage Indication
US, CND models
120 V AC, 60 Hz
AEP, UK, RU models
230 V AC, 50/60 Hz
AUS model
230 – 240 V AC, 50/60 Hz
KR model
220 V AC, 60 Hz
TH model
220 V AC, 50/60 Hz
E3, E51, SP models
110 – 120 V, 220 – 240 V AC, 50/60 Hz
Tape Cassette Mechanism Deck 
(CMAL5Z220C)
MAIN board
Front Panel
Ver. 1.2
Page of 62
Display

Click on the first or last page to see other CMT-DX2D / HCD-DX2D service manuals if exist.