CMT-DV2D, HCD-DV2D - Sony Audio Service Manual (repair manual). Page 4

Read Sony CMT-DV2D / HCD-DV2D Service Manual online

4
HCD-DV2D
SECTION 1
SERVICING NOTES
The laser diode in the optical pick-up block may suffer electrostatic
break-down because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the human body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
NOTES  ON  LASER  DIODE  EMISSION  CHECK
The laser beam on this model is concentrated so as to be focused on
the disc reflective surface by the objective lens in the optical pick-
up block. Therefore, when checking the laser diode emission,
observe from more than 30 cm away from the objective lens.
LASER  DIODE  AND  FOCUS  SEARCH  OPERATION
CHECK
Carry out the “S curve check” in “CD section adjustment” and check
that the S curve waveforms is output three times.
NOTES  ON  HANDLING  THE  OPTICAL  PICK-UP
BLOCK  OR  BASE  UNIT
MODEL  IDENTIFICATION
– Back Panel –
Power requirement 
indication
• Abbreviation
AUS
: Australian model.
CND
: Canadian model.
E2
: 120 V AC area in E model.
E3
: 240 V AC area in E model.
E51
: Chilean and Peruvian model.
KR
: Korea model.
RU
: Russian model.
SP
: Singapore model.
TW
: Taiwan model.
•  SERVICE POSITION OF THE TAPE CASSETTE MECHANISM DECK
DISC TRAY  LOCK
The disc tray lock function for the antitheft of an demonstration
disc in the store is equipped.
Procedure :
1. Press the  ?/1  button to turn the set ON.
2. Press the  DVD u button to select “DVD”
3. Set disc on the tray, press the  x  button and the  Z  button
simultaneously for five seconds.
4. The message “LOCKED” is displayed the tray is locked.
5. To release from this mode, press the  x  button and the  Z
button simultaneously for five seconds again.
6. The message “UNLOCKED” is displayed and the tray is
unlocked.
Note:
When “LOCKED” is displayed, the slot lock is not released by
turning power on/off with the  ?/1  button.
Tape Cassette Mechanism Deck 
(CMAL5Z220C)
MAIN board
Front Panel
Ver. 1.2
Model
Power Voltage Indication
US, CND models
120 V AC, 60 Hz
AEP, UK, RU models
230 V AC, 50/60 Hz
SP, E2, E3, E51  models
110 – 120 V/220 – 240V AC, 50/60 Hz
TW model
120 V AC, 50/60 Hz
KR model
220 V AC, 60 Hz
AUS model
230 – 240 V AC, 50/60 Hz
Page of 71
Display