CMT-DC1, HCD-DC1 - Sony Audio Service Manual (repair manual). Page 13

Read Sony CMT-DC1 / HCD-DC1 Service Manual online

HCD-DC1
13
Note:
Confirm each contents of this section first of all. If the results are
not satisfied, do the adjustment.
1.
Demagnetize the record/playback head with a head
demagnetizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
After the adjustments, apply suitable locking compound to the
parts adjust.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5.
The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6.
The adjustments should be performed for both L-CH and R-
CH.
7.
Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
Record/Playback Head Azimuth Adjustment
Procedure:
1.
Mode:  Playback
SECTION  5
ELECTRICAL  ADJUSTMENT
2.
Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3.
Mode: Playback
4.
Repeat step 1 to 3 in playback (REV) mode.
5.
After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location:
0 dB=0.775 V
DECK  SECTION
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
set
MAIN board
SPEAKER terminals (SJ301)
L-CH, R-CH
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
Screw
position
L-CH
peak
within
1 dB
Output
level
L-CH
peak
R-CH
peak
within
1 dB
Screw
position
R-CH
peak
set
test tape
P-4-A100
(10 kHz, –10 dB)
R-CH
oscilloscope
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
SPEAKER terminals (SJ301)
L-CH
forward
reverse
Page of 51
Display