Read Sony CMT-CP101 / CMT-CP101K / HCD-CP101 Service Manual online
HCD-CP101
12
SECTION 4
TEST MODE
Start
REC pause for 3 seconds
FWD REC
Fast forward
REV Play
REC pause for 3 seconds
REV REC
Rewind
FWD Play
Shut off
Shut off
Shut off
Shut off
1 minute
3 minutes
1 minute
3 minutes
Start
Open the disc tray
Close the disc tray
Play the last track
[COLD RESET]
• The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning
the set to the customer.
the set to the customer.
Procedure:
1. Turn ON the power.
2. Press three buttons of
1. Turn ON the power.
2. Press three buttons of
x
(TAPE),
x
(CD), and
[BAND]
si-
multaneously.
3. The set is reset.
[LIQUID CRYSTAL DISPLAY ALL LIT CHECK MODE]
Procedure:
1.
1.
Set to standby state.
2.
Press three buttons of
x
(TAPE),
x
(CD), and
[TUNING MODE]
simultaneously.
3.
Liquid crystal display are all turned on.
4.
To exit from this mode, press the
I/1
button to turn the power
OFF.
[TAPE DECK AGING MODE]
This mode can be used for operation check of tape deck section.
Procedure:
1.
1.
Set a tape in the tape deck.
2.
Set to standby state.
3.
Press three buttons of
x
(TAPE),
x
(CD), and
[TUNING +]
simultaneously.
4.
The aging is executed in bellow sequence.
5.
To exit from the aging mode, press the
I/1
button to turn the
power OFF.
Aging mode sequence:
[CD AGING MODE]
This mode can be used for operation check of CD section.
Procedure:
1.
1.
Load a CD disc.
2.
Set to standby state.
3.
Press three buttons of
x
(TAPE),
x
(CD), and
[TUNING --]
simultaneously.
4.
The aging is executed in bellow sequence.
5.
To exit from the aging mode, press the
I/1
button to turn the
power OFF.
Aging mode sequence:
[CHANGE-OVER MD/VIDEO]
Procedure:
1.
1.
Set to standby state.
2.
Press the
x
(CD) and the
[FUNCTION]
buttons simul-
taneously.
The function changes over to MD or VIDEO by turns.
The function changes over to MD or VIDEO by turns.
[CHANGE-OVER THE AM TUNING INTERVAL]
(EXCEPT AEP and UK models)
(EXCEPT AEP and UK models)
• The AM tuning interval can be changed over 9 kHz or 10 kHz.
Procedure:
1. Press the
Procedure:
1. Press the
I
/
1
button to turn the power ON.
2. Select the function “TUNER”, and press the
[BAND]
button
to select the BAND “AM”.
3. Press the
I
/
1
button to turn the power OFF.
4. Change over to 9 kHz:
Press the
[TUNING --]
and the
x
(CD) buttons simultaneously.
Change over to 10 kHz:
Press the
Press the
[TUNING +]
and the
x
(CD) buttons simultaneously.
Click on the first or last page to see other CMT-CP101 / CMT-CP101K / HCD-CP101 service manuals if exist.