CMT-C7NT, HCD-C7NT - Sony Audio Service Manual (repair manual). Page 42

Read Sony CMT-C7NT / HCD-C7NT Service Manual online

42
HCD-C7NT
Procedure:
1. Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin
6
 (VC) on the BD (MD) board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Press the  M
 “R”
  button to move the optical pick-up outside
the pit.
4. Press the  . 
“R”
  or  >
 “R”
  button to display “EF MO
ADJUST” (C07).
5. Press the
ENTER/YES “R”
button to display “EFB =     MO-
R”. (Laser power READ power/Focus servo ON/tracking servo
OFF/spindle (S) servo ON)
6. Press the  . 
“R”
  or  >
 “R”
  button so that the waveform of
the oscilloscope becomes the specified value.
(When the  . 
“R”
  or  >
 “R”
  button  is pressed, the     of
“EFB=    ” changes and the waveform changes) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the waveform
so that the specified value is satisfied as much as possible.
(Read power traverse adjustment)
Traverse Waveform
7. Press the  
ENTER/YES “R”  
button and save the result of
adjustment to the non-volatile memory (“EFB =      SAVE”
will be displayed for a moment. Then “EFB =     MO-W” will
be displayed).
8. Press the  . 
“R”
  or  >
 “R”
  button so that the waveform of
the oscilloscope becomes the specified value.
(When the  . 
“R”
  or  >
 “R”
  button is pressed, the     of
“EFB=    ”  changes and the waveform changes) In this
adjustment, waveform varies at intervals of approx. 2%. Adjust
the waveform so that the specified value is satisfied as much as
possible. (Write power traverse adjustment)
Traverse Waveform
9. Press the  
ENTER/YES “R”  
button, and save the adjustment
results in the non-volatile memory. (“EFB =     SAVE” will be
displayed for a moment)
10. “EFB =     MO-P” will be displayed.
The optical pick-up moves to the pit area automatically and
servo is imposed.
A
B
VC
Specification A = B
11. Press the  .
 “R”
  or  >
 “R”
  button until the waveform of
the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
Traverse Waveform
12. Press the  
ENTER/YES “R”  
button, and save the adjustment
results in the non-volatile memory. (“EFB =     SAVE” will be
displayed for a moment)
Next “EF MO ADJUST” (C07) is displayed. The disc stops
rotating automatically.
13. Press the  
MD 
Z  button and take out the disc.
14. Load the check disc (TDYS-1).
15. Press the  .
 “R”
  or  >
 “R”
  button to display “EF CD
ADJUST” (C08).
16. Press the  
ENTER/YES “R”  
button to display “EFB =     CD”.
Servo is imposed automatically.
17. Press the  . 
“R”
  or  >
 “R”
  button so that the waveform of
the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
Traverse Waveform
18. Press the  
ENTER/YES “R”  
button, display “EFB =     SAVE”
for a moment and save the adjustment results in the non-volatile
memory.
Next “EF CD ADJUST” (C08) will be displayed.
19. Press the  
MD 
Z  button and take out the  check disc.
Adjustment Location: BD (MD) board (see page 44)
A
B
VC
Specification A = B
A
B
VC
Specification A = B