– 12 –
2. Turn the adjustment screw for the maximum output levels. If
these levels do not match, turn the adjustment screw until both
of output levels match together within 1dB.
of output levels match together within 1dB.
Screw
position
position
L-CH
peak
peak
within
1dB
1dB
output
level
level
L-CH
peak
peak
R-CH
peak
peak
within
1dB
1dB
Screw
angle
angle
R-CH
peak
peak
3. Mode : Forward Playback
4. Change the reverse playback mode and repeat the steps 1 to 3.
5. After the adjustment, lock the adjustment screw with suitable
5. After the adjustment, lock the adjustment screw with suitable
locking compound.
Adjustment Location :
–record/playback head (Deck A and B)
Deck A
Deck B
forward
reverse
Adjustment Screw
Tape Speed Adjustment
Procedure :
•
Perform high speed adjustment before normal speed adjustment.
Mode : Playback
DECK A
DECK B
Speed
Deck
Adjustment
Frequency counter
*High
A
RV652
5,940 to 6,060 Hz
B
RV652
Normal
A
RV651
2,990 to 3,030 Hz
B
RV651
* Continuous to press HIGH SPEED DUBBING switch (S507) in
playback mode : High speed playback.
Frequency difference between the beginning and the end of the tape
should be within ± 3%.
Frequency difference between deck A and deck B the beginning of
the tape should be within 1.5%.
should be within ± 3%.
Frequency difference between deck A and deck B the beginning of
the tape should be within 1.5%.
Adjustment Location : AUDIO board (see page 13)
Playback Level Adjustment
Procedure :
Mode : Playback
Mode : Playback
DECK A
DECK B
Deck A is RV311 (L-CH) and RV411 (R-CH), deck B is RV301 (L-
CH) and RV401 (R-CH) so that adjustment within adjustment level
as follows.
CH) and RV401 (R-CH) so that adjustment within adjustment level
as follows.
Adjustment Level :
OUTPUT level : –3.5 ± 0.5 dB (0.489 to 0.546 V)
Level Difference between Channels : within 0.5 dB
OUTPUT level : –3.5 ± 0.5 dB (0.489 to 0.546 V)
Level Difference between Channels : within 0.5 dB
Confirm the OUTPUT level dose not change in playback mode while
changing the mode from playback to stop several times.
changing the mode from playback to stop several times.
Adjustment Location : AUDIO board (see page 13)
set
+
–
–
test tape
P-4-A100
(10kHz, -10dB)
P-4-A100
(10kHz, -10dB)
MD OUT
Oscilloscope
L-CH
R-CH
V
H
+
–
screen pattern
in phase
45
°
90
°
135
°
180
°
good
wrong
set
test tape
WS-48B
(3 kHz, 0 dB)
WS-48B
(3 kHz, 0 dB)
MD OUT
+
–
–
frequency counter
set
+
–
–
test tape
P-4-L300
(315 Hz, 0 dB)
P-4-L300
(315 Hz, 0 dB)
MD OUT
level meter