CFT-22 - Sony Audio Service Manual (repair manual). Page 8

Read Sony CFT-22 Service Manual online

– 8 –
 TUNER SECTION
 AM Section
BAND switch
: AM
Volume
: MIN
AM RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
 FM Section
BAND switch
: FM
Volume
: MIN
FM RF signal
generator
22.5kHz frequency deviation by 
400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01
µ
F
set
32
level meter
earphone jack
+
r
Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally done
by the trimmer capacitors.
no mark    : AEP, E, UK model
(         )     : Italian model
[         ]     : Saudi Arabia model
AM IF ALIGNMENT
Adjust for a maximum reading on level meter.
T1
                455kHz
        (455kHz)
   [455kHz]
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
                520kHz 
        (516kHz)
    [520kHz]
CT4
            1,680kHz
     (1,630kHz)
 [1,680kHz]
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
               620kHz
       (620kHz)
    [620kHz]
CT3
            1,400kHz
    (1,400kHz)
 [1,400kHz]
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
           87.0MHz 
   (87.35MHz)
    [87.35MHz]    
CT2
        108.3MHz
 (108.25MHz)
[107.8MHz]
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
          87.0MHz 
  (87.35MHz)
[87.35MHz]
CT1
       108.3MHz
(108.25MHz)
[107.8MHz]
Adjustment Location : Main board
Page of 16
Display