CFS-E2 - Sony Audio Service Manual (repair manual). Page 5

Read Sony CFS-E2 Service Manual online

CFS-E2
Tape Speed Adjustment
Procedure:
Mode :
 FWD playback
Adjustment Value :
 normal tape speed
Confirm that the frequency difference between the tape top and
tape end is within 1.5 % (45 Hz).
Adjustment element :
 RV601
PRECAUTION
Clean the following parts with a denatured-alchool-moistened
swab:
record/playback head
erase head
pinch rollers
playback head
rubber belts
idlers
capstan
Demagnetize the record/playback head with a head
demagnetizer.
(Do not bring a head demagnetiger close to the erase head.)
Do not use a magnetized screwdriver for the adjustments.
After the adjustments, apply suitable locking compound to the
parts adjusted.
Perform adjustment under the specified voltage (DC6V) unless
otherwise specified.
Torque Measurement
Tape Tension
SECTION 3
MECHANICAL ADJUSTMENTS
Tension Meter
CQ-403A
Mode
FWD
Meter reading
70g or more
Meter reading
22.5 to 55g · cm
2.5 to 5g · cm
45 to120g · cm
Mode
FWD
FWD
back tension
FF, REW
Torque Meter
CQ-102C
CQ-102C
CQ-201B
4-1.
TAPE RECODER SECTION
0 dB = 0.775 V
PRECAUTION
1.
Adjustments should be performed in the order given. (Generally
playback circuit adjustments should be completed before
preforming recording circuit adjustments.)
2.
Adjustments should be performed for both L-ch and R-ch.
(Switches and controls should be set as follows unless otherwise
specified.)
Switch position
FUNCTION
: TAPE (RADIO OFF)
TONE
: Maximum
MEGA BASS : ON
VOLUME
: Maximum
Test tape
SECTION 4
ELECTRICAL ADJUSTMENTS
Test Tape
WS-48A
Used for
Tape speed adjustment
Signal
3 kHz, 0 dB
Frequency counter
2,980 to 3,020 Hz
DECK
B
4-2.
TUNER SECTION
0 dB = 1 µV
AM section
FUNCTION
: RADIO
BAND
: AM
FM section
FUNCTION
: RADIO
BAND
: AM
Repeat the above adjustments unit the level meter reading is
maximized.
AM Tracking Adjustment
Make adjustment unit the level meter defection is maximized.
ANT2
620kHz
CT1
1,400 kHz
AM Frequency Coverage Adjustment
Make adjustment unit the level meter defection is maximized.
T1
520kHz (520kHz)
CT4
1,710kHz (1,680kHz)
FM Frequency Coverage Adjustment
Make adjustment unit the level meter defection is maximized.
L2
86.5MHz (87.0MHz)
CT3
109.5MHz (107.8MHz)
FM Tracking Adjustment
Make adjustment unit the level meter defection is maximized.
L1
86.5MHz (87.0MHz)
CT2
109.5MHz (107.8MHz)
FM Separation Adjustment
Adjustment method:
FUNCTION switch 
⋅⋅⋅⋅⋅
 FM
Adjust T2 unit the L-channel output minized.
— 5 —
— 6 —
— 7 —
CT2
L1
CT3
S101
CT4
RV1
T2
T1
RV601
RV301
CT1
L2
Adjustment location :
 MAIN board (Component side)
FM VCO Adjustment
Procedure:
1.
Connect frequency counter to the positions shown below.
2.
Tune the set to 98MHz.
3.
Adjust RV1 for 75.5 to 76.5kHz reading on the frequency
counter.
(        ) : AEP model
(        ) : AEP model
(        ) : AEP model
Ver 1.2  2001. 04
Page of 18
Display