Read Sony CFS-828SMK2 Service Manual online
10
CFS-828SMK2
Adjustment Location: See page 11
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
L9
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
86.5 MHz
CT2
109.5 MHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
86.5 MHz
CT1
109.5 MHz
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455 kHz
MW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520 kHz
CT4
1,680 kHz
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
600 kHz
CT3
1,400 kHz
SW1 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L6
2.2 MHz
CT6
7.3 MHz
SW1 TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L5
2.2 MHz
< confirmation >
7.3 MHz
SW2 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L8
6.8 MHz
CT8
22.5 MHz
SW2 TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L7
6.8 MHz
< confirmation >
22.5 MHz
TUNER SECTION 0 dB = 1 µV
Common Setting:
SOUND SELECT control: FLAT
VOLUME control: MAX
MAXI BASS switch: OFF
VOLUME control: MAX
MAXI BASS switch: OFF
• FM Section
BAND switch: FM
• MW Section
BAND switch: MW
FINE TUNING (RV2): mechanical center
FINE TUNING (RV2): mechanical center
• SW1/SW2 Section
BAND switch: SW1 or SW2
FINE TUNING (RV2): mechanical center
FINE TUNING (RV2): mechanical center
• Common Connecting Level Meter
telescopic
antenna terminal
antenna terminal
0.01
µ
F
FM RF signal
generator
generator
75kHz frequency deviation
by 1kHz signal
Output level: as low as possible
by 1kHz signal
Output level: as low as possible
set
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
AM RF signal
generator
generator
400Hz, 30%
AM modulation
Output level: as low as possible
AM modulation
Output level: as low as possible
telescopic
antenna terminal
antenna terminal
12pF
AM RF signal
generator
generator
400Hz, 30%
AM modulation
Output level: as low as possible
AM modulation
Output level: as low as possible
set
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
done by the trimmer capacitors.