ADJUSTMENTS
4-1. MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
playback head
pinch roller
erase head
rubber belt
capstan
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
3. Do not use a magnetized screwdriver for adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
Torque
Torque Meter
Meter Reading
Playback
CQ-102C
18 – 60 g • cm
(0.25 – 0.83 oz• inch)
Back Tension
CQ-102C
1 – 5 g • cm
(0.014 – 0.069 oz• inch)
Rewind
CQ-201B
45 – 95 g • cm
Fast Forward
(0.63 – 1.31 oz• inch)
Tape Tension  Measurement
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 60g (2.12 oz)
4-2. ELECTRICAL ADJUSTMENTS
  TAPE SECTION
1. The adjustments should be performed in the order give in the
service manual. (As a general rule, playbak circuit adjustment
should be completed before performing recording circuit adjust-
ment.)
2. The adjustments should be performed for both L-CH and R-CH
unless otherwise indicated.
• Switch location
FUNCTION switch
• • • • • • • • • • • • • • • • • 
TAPE (RADIO OFF)
PRESET MODE
• • • • • • • • • • • • • • • • • • • • • 
MANUAL
GRAPHIC EQUALIZER
• • • • • • • • 
center click
BALANCE
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • 
center click
VOLUME
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 
MAX
MEGA BASS
• • • • • • • • • • • • • • • • • • • • • • • • •   
mechanical center
Standard Output Level
Output terminal
PHONES
SP (FRONT) OUT
Load impedance
32
6
Output signal level
0.25V (–10dB)
0.775V (0dB)
Test Tape
Type
Signal
Used for
 WS-48A
3kHz, 0dB
Tape Speed Adjustment
 0dB=0.775V
Tape Speed Adjustment
Procedure :
Mode : Playback
(Normal speed)
1. Deck A to playback mode.
2. Adjust the RV303 for 2,985 – 3,015Hz reading on digital fre-
quency counter.
3. Frequency difference between the beginning and the end of the
tape should be within 1% (30Hz).
(High speed)
4. Deck B to record mode.
5. Deck A to high speed playback mode.
6. Confirm that the reading of the digital voltmeter becomes 5,500
– 6,500Hz.
7. Frequency difference between the beginning and the end of the
tape should be within 1% (30Hz).
Adjustment Location :
set
test tape
WS-48A
(3kHz, 0dB)
32 
digital frequency 
counter
phones jack
IC201
RV303 : Tape Speed Adjustment