Read Sony CFS-1085S Service Manual online
10
CFS-1085S
TUNER SECTION
MW Section
Procedure :
BAND Switch
: MIN
FINE TUNE control
: mechanical center
SW Section
Procedure :
BAND Switch
: SW1, SW2
FINE TUNE control
: mechanical center
FM Section
Procedure :
BAND Switch
: FM
FINE TUNE control
: mechanical center
(
) : Saudi Arabia model
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455kHz
MW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520kHz
CT4
1,680kHz
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
620kHz
CT3
1,400kHz
SW1 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L6
2.2MHz
CT6
7.3MHz
SW1 TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L5
2.2MHz
Confirmation
7.3MHz
SW2 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L8
6.8MHz
CT8
22.5MHz
SW2 TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L7
6.8MHz
Confirmation
22.5MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
86.5MHz (87.35MHz)
CT2
109.5MHz (107.8MHz)
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
86.5MHz (87.35MHz)
CT1
109.5MHz (107.8MHz)
AM RF signal
generator
generator
30% amplitude modulation by
400Hz signal.
Output level : as low as possible
400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
antenna
terminal
12PF
Adjustment Location : Mechanism deck
z
Switch location
FUNCTION switch................ TAPE (RADIO OFF)
SOUND SELECT.................. FLAT
VOLUME.............................. mechanical center
MEGA BASS......................... OFF
SOUND SELECT.................. FLAT
VOLUME.............................. mechanical center
MEGA BASS......................... OFF
TUNER SECTION
AM RF signal
generator
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
signal.
Output level : as low as possible
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
set
32
Ω
J301 (phones)
level meter
FM RF signal
generator
generator
22.5kHz frequency deviation by
1kHz signal.
Output level : as low as possible
1kHz signal.
Output level : as low as possible
telescopic
antenna
terminal
antenna
terminal
0.01
µ
F
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
done by the trimmer capacitors.