– 10 –
FM FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
86.5MHz
(87MHz)
CT1 – 4
109.5MHz (108.30MHz)
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
86.5MHz
(87MHz)
CT1 – 3
109.5MHz (108.30MHz)
AEP, UK model
LW FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
145kHz
CT6
300kHz
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L6 – 2
145kHz
CT5
300kHz
Adjustment Location : MAIN board (Component side)
[MAIN BOARD] (Component side)
CT1–3 : FM Tracking Adjustment
CT1–1 : MW Tracking Adjustment
CT5 : LW Tracking Adjustment
L6–2: LW Tracking Adjustment
L6–1: MW Tracking Adjustment
T1 : AM  IF Alignment 
L2 : FM Frequency Coverage Adjustment
CT1–2 : MW Frequency Coverage Adjustment
CT1–4 : FM Frequency
             Coverage Adjustment
L3 : MW Frequency Coverage Adjustment
CT6 : LW Frequency 
         Coverage Adjustment
L4 : LW Frequency 
       Coverage Adjustment
L1 : FM Tracking Adjustment
[MAIN BOARD] (Component side)
CT1–3 : FM Tracking Adjustment
CT1–1 : AM Tracking Adjustment
L6 : AM  Tracking Adjustment
T1 : AM  IF Alignment 
L2 : FM Frequency Coverage Adjustment
CT1–2 : AM Frequency Coverage Adjustment
CT1–4 : FM Frequency
             Coverage Adjustment
L3 : AM Frequency Coverage Adjustment
L1 : FM Tracking Adjustment
AEP, UK model
US model