CFM-20L - Sony Audio Service Manual (repair manual). Page 8

Read Sony CFM-20L Service Manual online

8
CFM-20L
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
LW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455kHz
LW FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
145kHz
CT6
300kHz
LW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
160kHz
CT5
260kHz
FM FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
87.00MHz
CT1
108.30MHz
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.00MHz
CT2
108.30MHz
Adjustment Location : MAIN board
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
L5
10.7MHz
[MAIN BOARD]
(Conductor side)
CT3 : LW Frequency Coverage Adjustment
         (Set to mechanical center)
CT4 : LW Tracking Adjustment
         (Set to mechanical center)
CT2: FM Tracking Adjustment
CT1 : FM Frequency 
         Coverage Adjustment
[MAIN BOARD]
(Component side)
L5 : FM IF Adjustment
T1: LW IF Adjustment
L1: FM Tracking Adjustment
L3: LW Tracking Adjustment
L4 : LW Frequency 
         Coverage Adjustment
CT5 : LW Tracking Adjustment
CT6 : LW Frequency 
         Coverage Adjustment
L2: FM Frequency 
         Coverage Adjustment
Page of 21
Display