CFM-20 (serv.man2) - Sony Audio Service Manual (repair manual). Page 13

Read Sony CFM-20 (serv.man2) Service Manual online

9
CFM-20
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455kHz
AM FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520kHz<516kHz>
CT3
1,680kHz (1780kHz) <1,630kHz>
AM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
600kHz
CT4
1,400kHz (1500kHz)
FM FREQUENCY COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
87.00MHz (86.50MHz) <87.35MHz>
CT1
108.30MHz (109.50MHz) <108.25MHz>
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.00MHz (86.50MHz) <87.35MHz>
CT2
108.30MHz (109.50MHz) <108.25MHz>
(            )  : C&SA, MX, TW model
<            >  : IT model
Adjustment Location : MAIN board
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
L5
10.7MHz
(            )  : C&SA, MX, TW model
<            >   : IT model
[MAIN BOARD]
(Conductor side)
CT3 : AM Frequency Coverage Adjustment
CT4 : AM Tracking Adjustment
CT2: FM Tracking Adjustment
CT1 : FM Frequency 
         Coverage Adjustment
[MAIN BOARD]
(Component side)
L5 : FM IF Adjustment
T1: AM IF Adjustment
L1: FM Tracking Adjustment
L3: AM Tracking Adjustment
L4 : AM Frequency 
         Coverage Adjustment
L2: FM Frequency 
         Coverage Adjustment
• Abbreviation
MX
: Mexican
IT
: Italian
TW
: Taiwan
C&SA : Central and South America