CFD-Z125, CFD-Z135 - Sony Audio Service Manual (repair manual). Page 2

Read Sony CFD-Z125 / CFD-Z135 Service Manual online

— 2 —
Battery life
For CD radio cassette-corder:
FM recording
Sony R20P : approx. 7 h
Sony alkaline LR20 : approx. 14.5 h
Tape playback
Sony R20P : approx. 3.5 h
Sony alkaline LR20 : approx. 8 h
CD playback
Sony R20P : approx. 2 h
Sony alkaline LR20 : approx. 4.5 h
Dimensions
Approx. 622 
×
 275 
×
 230 mm (w/h/d)
(24 
1
/
2
 
×
 10 
7
/
8
 
×
 9 
1
/
8
 inches) (incl. projecting
parts)
Mass
Approx. 6.8 kg (15 lb.) (incl. batteries)
Supplied accessories
AC power cord (1)
Remote controller (1) (CFD-Z135 only)
Design  and specifications are subject to change without notice.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 
!
 OR DOTTED LINE WITH
MARK 
!
 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUBLISHED BY SONY.
    After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE
    The AC leakage from any exposed metal part to earth ground
and from all exposed metal parts to any exposed metal part having
a return to chassis, must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1.
A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2.
A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3.
Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit” indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
SAFETY  CHECK-OUT
To Exposed Metal 
Parts on Set
0.15 
µ
F
1.5 k
AC
Voltmeter
(0.75 V)
Earth Ground
Fig. A.  Using an AC voltmeter to check AC leakage.
CAUTION
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous radiation
exposure.
TABLE OF CONTENTS
1. SERVICE NOTES
···························································· 3
2. GENERAL
·········································································· 4
3. DISASSEMBLY
3-1.
Rear Cabinet ······································································· 9
3-2.
CD Block ·········································································· 10
3-3.
Main Board, SP Terminal Board ······································ 10
3-4.
CD Decoder Board, Lamp Board ····································· 11
3-5.
Optical Pick-up Section (KSM-213CDM/Z-NP) ············· 11
3-6.
Optical Pick-up (KSS-213C/Z-N) ···································· 12
3-7.
Motor Board, Sled Motor (M702) ···································· 12
3-8.
Front Board, Sensor Board ··············································· 13
3-9.
Mechanism Deck (MF-Z125) ··········································· 13
3-10. Belt, Capstan/Reel Motor (M601) ···································· 14
3-11. Cassette Door ··································································· 14
4. DIAL POINTER SETTING
·········································· 15
5. ADJUSTMENTS
5-1.
Mechanical Adjustment ···················································· 16
5-2.
Electrical Adjustment
Tape Deck Section ···························································· 16
Tuner Section ···································································· 18
CD Section ······································································· 20
6. DIAGRAMS
6-1.
Circuit Boards Location ··················································· 23
6-2.
Block Diagram ································································· 24
6-3.
Printed Wiring Board —CD Section — ··························· 29
6-4.
Schematic Diagram — CD Section — ····························· 32
6-5.
Schematic Diagram  — Main Section — ························· 35
6-6.
Printed Wiring Board —Main Section — ························ 39
6-7.
Printed Wiring Board —Front Section — ························ 43
6-8.
Schematic Diagram —Front Section — ··························· 45
6-9.
IC Pin Function Description ············································· 47
7. EXPLODED VIEWS
7-1.
Back Cabinet Section ······················································· 49
7-2.
Front Panel Section ·························································· 50
7-3.
CD Block Section ····························································· 51
7-4.
Optical Pick-up Section (KSM-213CDM/Z-NP) ············· 52
7-5.
Mechanism Deck Section-1 ·············································· 53
7-6.
Mechanism Deck Section-2 ·············································· 54
7-7.
Speaker Section ································································ 55
8. ELECTRICAL PARTS LIST
······································· 56
Page of 41
Display