CFD-W57L - Sony Audio Service Manual (repair manual). Page 17

Read Sony CFD-W57L Service Manual online

– 17 –
  TUNER SECTION     0 dB = 1 
µ
V
• FM Section
Setting:
BAND switch: FM
22.5 kHz frequency
deviation by 400 Hz signal
Output level : as low as possible
• MW/LW Section
Setting:
BAND switch: MW or LW
30% amplitude
moudulation by 400 Hz signal
Output level : as low as possible
• Connecting Level Meter (FM, MW and LW)
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
(65 MHz)
Reading on Digital voltmeter
1.4 
±
 0.2 V
3.5 
±
 0.1 V
(7.3 
±
 0.2 V)
Adjustment Part
<confirmation>
L2
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz (68 MHz)
108 MHz (102 MHz)
MW FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
531 kHz
1,611 kHz
Reading on Digital voltmeter
0.9 
±
 0.1 V
5.7 
±
 0.1 V
Adjustment Part
L4
CT2
MW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-1
CT4
621 kHz
1,404 kHz
LW FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
153 kHz
279 kHz
Reading on Digital voltmeter
0.6 
±
 0.15 V
5.7 
±
 0.1 V
Adjustment Part
<confirmation>
CT3
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-2
CT5
162 kHz
261 kHz
(      ) : East European model
Adjustment Location: See page 18.
antenna terminal
(FH1)
FM RF signal
generator
0.01 
µ
F
set
digital
voltmeter
100 k
JW44
TP (VT)
phones jack
set
32 
level meter
(range: 0.5-5 V ac)
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
• Connecting Digital Voltmeter (FM, MW and LW)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
Page of 49
Display

Click on the first or last page to see other CFD-W57L service manuals if exist.