Focus Bias Check
This check is to be done when the optical block replaced.
Check Procedure:
1. Connect the oscilloscope to test point TP (VC) and TP (RF) on
MAIN board.
2. Put the set into test mode.
3. Opitical pick-up setting to the center by + or – button pushing.
4. Insert disk (YEDS-18) and press 
^ button.
5. Press the MODE button. (Tracking servo ON)
6. Check that the oscilloscope wavewform is as shown in the figure
below (eye pattern).
A good eye pattern means that the diamond shape (
) in the
center of the waveform can be clearly distinguished.
7. Release test mode after adjustment is completed.
• RF signal reference waveform (eye pattern)
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensivity.
[MAIN BOARD] (Conductor side)
5-4.
REFERENCE
Focus/Tracking Gain Check
Adjustment Location : MAIN board (Component side)
(See page 16)
A frequency response analyzer is necessary in order to perform this
check exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem.
Focus/Tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
Tracking
Gain
Symptoms
Focus
•  The time until music starts
becomes longer for STOP ➡
CD 
^ or automatic
selection (
0 , ) buttons
pressed). (Normally takes
about 2 seconds.)
•  Music does not start and disc
continues to rotate for STOP
➡ CD ^ or automatic
selection (
0 , ) buttons
pressed.)
•  Sound is interrupted during
PLAY. Or time counter
display stops progressing.
•  More noise during 2-axis
device operation.
low
high
low or high
low
low
high
Check Procedure:
1. Keep the set horizontal.
2. Inset disk (YEDS-18) and press 
^ button.
3. Connect an oscilloscope to TP (FE) and TP (VC) on the MAIN
board.
4. Check that the waveform is as shown in the figure below. (Focus
waveform)
VOLT/DIV : 0.2V
TIME/DIV : 500ns
0.9Vp-p – 1.3Vp-p
TP(RF)
TP(VC)
+
Oscilloscope
(DC range)
TP
(RF)
TP(VC)