14
CFD-S36
TP
(RF)
TP
(VREF)
TP
(RF)
TP
(VREF)
– CD board (conductor side) –
Adjustment Location:
  CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
FOCUS BIAS CHECK
1. Connect the oscilloscope between IC701 pin 4 and pin qa (or
TP (RF) and TP (VREF).
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the CD N X button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (     ) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
Test Point:
RF level :
0.85 
± 0.2 Vp-p
VOLT/DIV : 50 mV (10 : 1 probe in use)
TIME/DIV : 500 nS
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
L6
L3
L4
CT5
JW18
CT4
CT3
CT2
L1
L2
T2
TP(JW1)
T1
L5
CT4, L3
TV-H/WB
FREQUENCY
COVERAGE
ADJUSTMENT
L6
AM
FREQUENCY
COVERAGE
ADJUSTMENT
CT3, L4
FM/TV-L
FREQUENCY
COVERAGE
ADJUSTMENT
CT2, L1
TV-H/WB
TRACKING
ADJUSTMENT
CT5, L5
AM
TRACKING
ADJUSTMENT
L2
FM/TV-L
TRACKING
ADJUSTMENT
T1
AM
IF
ADJUSTMENT
T2
FM/TV
IF
ADJUSTMENT
– MAIN board (component side) –