Read Sony CFD-S33L Service Manual online
– 17 –
– 8 –
– 15 –
– 16 –
CFD-S33L
r
SCHEMATIC DIAGRAM – MAIN SECTION (2/2) –
r
Waveforms
1
IC701
#¡
(RFO)
4
2
5
3
6
(PLAY MODE)
VOLT/DIV : 0.2 V AC
TIME/DIV : 0.5
TIME/DIV : 0.5
µ
sec
IC702
@∞
(XPCK)
VOLT/DIV : 1 V AC
TIME/DIV : 0.1 msec
TIME/DIV : 0.1 msec
VOLT/DIV : 1 V AC
TIME/DIV : 50
TIME/DIV : 50
µ
sec
VOLT/DIV : 1 V AC
TIME/DIV : 50
TIME/DIV : 50
µ
sec
VOLT/DIV : 1 V AC
TIME/DIV : 50
TIME/DIV : 50
µ
sec
VOLT/DIV : 0.2 V AC
TIME/DIV : 50 nsec
TIME/DIV : 50 nsec
IC702
@•
(RFCK)
IC702
#¡
(MNT3)
IC702
#™
(MNT1)
IC702
#∞
(XTAO)
1.0 – 1.4
Vp-p
Vp-p
4.8 Vp-p
242.0
µ
sec
5.3 Vp-p
140.5
µ
sec
5.3 Vp-p
140.5
µ
sec
5.3 Vp-p
140.5
µ
sec
1.1 Vp-p
16.9344 MHz
Note:
• All capacitors are in
• All capacitors are in
µ
F unless otherwise noted. pF:
µµ
F
50 WV or less are not indicated except for electrolytics
and tantalums.
and tantalums.
• All resistors are in
Ω
and
1
/
4
W or less unless otherwise
specified.
Note: The components identified by mark
!
or dotted
line with mark
!
are critical for safety.
Replace only with part number specified.
•
U
: B+ Line.
•
H
: adjustment for repair.
• Power voltage is dc 9 V and fed with regulated dc power
supply from external power voltage jack.
• Voltages and waveforms are dc with respect to ground
under no-signal (detuned) conditions.
no mark : CD STOP
no mark : CD STOP
• Voltages are taken with a VOM (Input impedance 10 M
Ω
).
Voltage variations may be noted due to normal produc-
tion tolerances.
tion tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal produc-
tion tolerances.
tion tolerances.
• Circled numbers refer to waveforms.
• Signal path.
• Signal path.
J
: CD