Read Sony CFD-S26L / CFD-S36L Service Manual online
13
CFD-S26L/S36L
digital
voltmeter
voltmeter
100 k
Ω
TP (VT)
i
jack (J321)
set
32
Ω
level meter
(range: 0.5–5 V ac)
(range: 0.5–5 V ac)
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
AM RF signal
generator
generator
TP (JW2)
FM RF signal
generator
generator
0.01
µF
set
TUNER SECTION 0 dB = 1 µV
• FM Section
Setting:
RADIO (BAND) button: FM
RADIO (BAND) button: FM
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
deviation by 1 kHz signal
output level : as low as possible
• AM Section
Setting:
RADIO (BAND) button: MW or LW
RADIO (BAND) button: MW or LW
30% amplitude
modulation by
400 Hz signal
modulation by
400 Hz signal
• Connecting Level Meter (FM, MW and LW)
• Connecting Digital Voltmeter (FM, MW and LW)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
done by the trimmer capacitors.
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.3 ± 0.3 V
3.0 ± 0.2 V
Adjustment Part
<confirmation>
L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
MW FREQUENCY COVERAGE
CHECK
Frequency Display
531 kHz
1,611 kHz
Reading on Digital voltmeter
1.0 ± 0.5 V
5.2 ± 0.6 V
Adjustment Part
<confirmation> <confirmation>
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-1
CT3
621 kHz
1,404 kHz
LW FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
153 kHz
279 kHz
Reading on Digital voltmeter
0.6 ± 0.3 V
5.0 ± 0.1 V
Adjustment Part
<confirmation>
L4
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-2
CT5
162 kHz
261 kHz
Adjustment Location: See page 14.