CFD-G70L - Sony Audio Service Manual (repair manual). Page 15

Read Sony CFD-G70L Service Manual online

15
CFD-G70L
Focus Bias Check
1. Connect the oscilloscope between TP (RF) and GND on CD
board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01) (CD)
3. Press the u button two times (LPC ON).
4. Confirm that the oscilloscope waveform is as shown in the fig-
ure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊) in the cen-
ter of the waveform can be clearly distinguished.
5. Press the u button.(LPC OFF)
6. Perform confirmation in step 4 again.
RF Signal Reference Waveform (eye pattern)
RF level
0.83 – 0.87 Vp-p (LPC ON)
0.82 – 0.88 Vp-p (LPC OFF)
VOLT/DIV : 200mV
TIME/DIV : 500 nS
CD SECTION
Perform all CD section check and all adjustments in the test mode.
How to put the set into CD test mode
1. Press the POWER button turn the set ON.
2. Press the FUNCTION button to select CD.
3. Set Tset mode by momentarlly shorting both side of TEST A.
4. Press the x button two times. The set is into CD test mode.
(
88 is displayed)
5. Turn the power off to release test mode.
When observing the eye pattern, set the oscilloscope for AC range
and raise certical sensitivity.
CONTROL-1 BOARD
S404
S402
S403
S401
KH402
D401
R401
R402
R403
R404
R407
 
 
 
SOUND
(TEST A)
MODE
GAME/LINE
GAME Xpand
GAME Xpand
TEST mode : momentarily short
(Conductor side)
1-68
Q701
C729
C730
R730
R728
R729
C704
R708
C72
8
R726
R707
C70
FB70
C736
C734
IC701
R709
C705
R704
R702
R711
R710
R703
R705
R701
C703
C731
R706
R727
R712
R7
C708
C751
JC703
C743
C744
C74
C742
JW707
C707
C717
C732
C702
C701
JW708
JW709
JW713
JW714
JW723
JW
JW725
JW726
C750
C
7
C747
JW711
C733
C706
JW712
JW710
oscilloscope
(AC range)
TP (RF)
(GND)
CD BOARD   (Conductor side)
TP (RF)
Page of 52
Display

Click on the first or last page to see other CFD-G70L service manuals if exist.