AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
( ): E4
AM FREQUENCY COVERAGE CHECK
Frequency Display
530 kHz
1,710 kHz
(530 kHz)
(1,610 kHz)
Reading on Digital voltmeter
1.0
± 0.1 V
5.3
± 0.8V
(1.0
± 0.1 V)
(4.8
± 0.8V)
Adjustment Part
< L 4 >
<confirmation>
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT3
620 kHz
1,400 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.3
± 0.4 V
3.0
± 0.3 V
Adjustment Part
<confirmation>
L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
• Abbreviation
E4 : 110-120V/220-240V AC changeable.
E4 : 110-120V/220-240V AC changeable.
Adjustment Location : Main board (See page 16)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
done by the trimmer capacitors.
TUNER SECTION
AM Section
Function switch : AM
Volume
Volume
: MIN
FM Section
Function switch : FM
Volume
Volume
: MIN
• Connecting Level Meter (FM and AM)
• Connecting Digital Voltmeter (FM and AM)
AM RF signal
generator
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
signal.
Output level : as low as possible
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
FM RF signal
generator
generator
33.75kHz frequency deviation by
1kHz signal.
Output level : as low as possible
1kHz signal.
Output level : as low as possible
telescopic
antenna
terminal
antenna
terminal
0.01
µF
0dB = 1
µV
J391 ( i jack)
set
32
Ω
level meter
(range: 0.5–5 V ac)
(range: 0.5–5 V ac)
digital
voltmeter
voltmeter
100 k
Ω
TP (VT)