Note on Schematic Diagram:
• All capacitors are in 
µ
F unless otherwise noted.  p: pF.
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
f
: internal component.
2
: nonflammable resistor.
C
: panel designation.
A
: B+ Line.
H
: adjustment for repair.
• Total current is measured with no cassette installed.
• Power voltage is dc 9 V and fed with regulated dc power
supply from battery terminal.
• Voltages and waveforms are dc with respect to ground
under no-signal (detuned) conditions.
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal produc-
tion tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal produc-
tion tolerances.
• Circled numbers refer to waveforms.
• Signal path.
F
: FM
f
: AM
E
: PB
a
: REC
J
: CD
• Abbreviation
AR
: Argentina model.
AUS
: Australian model.
CND : Canadian model.
E92
: Chilean and Peruvian model.
MX
: Mexican model.
SP
: Singapore model.
• WAVEFORMS
– TUNER Section –
SECTION 5
DIAGRAMS
5-1. Circuit Boards Location
BATT board
CD board
PDW board
MAIN board
L-R/REG board
TC board
TRANS board
LCD board
BATT COM board
POWER board
TUNER board
HEADPHONE board
CONTROL (CD) board
CONTROL (POWER) board
CONTROL (VOL) board
Note on Printed Wiring Boards:
• X
: parts extracted from the component side.
f
: internal component.
: Pattern from the side which enables seeing.
(The other layers' patterns are not indicated.)
1
 IC2 
w;
 (XOUT)
1.4 Vp-p
13.3 
µ
s
500 mV/DIV, 4 
µ
s/DIV
– TC Section –
2
 Q301 collector (TAPE REC)
3.1 Vp-p
18 
µ
s
1 V/DIV, 10 
µ
s/DIV
– CD Section –
3
 IC701 
rk
 (XOUT)
4.2 Vp-p
59 ns
1 V/DIV, 20 ns/DIV
– MAIN Section –
4
 IC801 
ua
 (XT2)
3.6 Vp-p
30.5 
µ
s
1 V/DIV, 10 
µ
s/DIV
5
 IC801 
ug
 (X2)
3.7 Vp-p
238 ns
1 V/DIV, 100 ns/DIV
Ver 1.3  2002. 09
Note:
The components identified by
mark 
0
 or dotted line with mark
0
 are critical for safety.
Replace only with part number
specified.
Note:
Les composants identifiés par
une marque 
0
  sont critiques
pour la sécurité.
Ne les remplacer que par une
pièce portant le numéro spécifié.
Page of 52
Display

Click on the first or last page to see other CFD-G35 service manuals if exist.