CFD-E75 - Sony Audio Service Manual (repair manual). Page 16

Read Sony CFD-E75 Service Manual online

16
CFD-E75
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
AM VCO VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
530 kHz
1.0 ± 0.05 V
Confirmation
1,710 kHz
5.3 ± 0.7 V
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L3
620 kHz
CT3
1,400 kHz
FM IF ADJUSTMENT
Adjust for a minimum reading on level meter
T2
10.7 MHz
FM VCO VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L2
108 MHz
3.0 ± 0.2 V
Confirmation
87.5 MHz
1.3 ± 0.3 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
87.5 MHz
CT1
108 MHz
Adjustment Location: TUNER and POWER board (See page 16)
TUNER  SECTION
0 dB=1 
µ
V
[AM]
Setting:
Function : RADIO
RADIO BAND button : AM
[FM]
Setting:
Function : RADIO
RADIO BAND button: FM
• Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer ca-
pacitors.
• Remove FM antenna in FM adjustment.
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: 
as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
3.2 
POWER board
CNP392 pin 
2
POWER board
CNP392 pin 
1
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: 
as low as possible
+
level meter
POWER board
CNP392 pin 
2
POWER board
CNP392 pin 
1
set
3.2 
0.01 
µ
F
TUNER board
TP (GND)
TUNER board
TP (ANT)
digital voltmeter
TP (VT)
TP (GND)
100 k
TUNER board
Page of 55
Display

Click on the first or last page to see other CFD-E75 service manuals if exist.