CFD-101 - Sony Audio Service Manual (repair manual). Page 18

Read Sony CFD-101 Service Manual online

– 18 –
Focus Bias Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
Procedure :
1. Connect the oscilloscope between TP (RF) and TP (VC).
2. Insert disc (YEDS-18) and push the 
fl button.
3. Adjust RV701 so that the oscilloscope waveform is maximum as
shown in the figure below (eye pattern).
• RF signal reference waveform (eye pattern)
  REFERENCE
Focus/Tracking Gain Adjustment
A frequency response analyzer is necessary in order to perform this
adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem. Therefore, do not perform this adjustment.
Focus/tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain is raised, the noise when the 2-axis device operates
increases.
• When gain is lowered, it is more susceptible to mechanical shock
and skipping occurs more easily.
When gain adjustment is off, the symptoms below appear.
oscilloscope
(DC range)
CD board
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
Adjustment Location : See page 20.
0V
1.3 ± 0.2 V
VOLT / DIV : 0.2 V
TIME / DIV : 500 nS
TP (RF)(IC702 
)
TP (VC)(IC701 
$•
)
• The time until music starts becomes longer
for 
π m fl on automatic selection.
(
≠, ± buttons pressed.)
(Normally, takes about 2 seconds.)
• Music does not start and disc continues
to rotate for 
π m fl or automatic
selection.
(
≠, ± buttons pressed.)
• Sound is interrupted during PLAY. Or
time counter display stops progressing.
• More noise during 2-axis device
operation.
Symptoms
Gain
Focus
Tracking
low
low or high
low
low
high
high
Page of 38