E-F Balance Check
Connection:
Procedure:
1.
Connect an oscilloscpe to test point TP (TE1) and TP (VC) on
the BD board.
2.
Turn the power on.
3.
Put the disc (PATD-012) in to playback the number two track.
4.
Press the 
[TIME]
 button.  (The tracking servo and the sledding
servo are turned OFF)
5.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse Waveform
6.
Press the 
[TIME]
 button. (The tracking servo and sledding servo
are turned ON)
Confirm the C (DC voltage) is almost equal to the A (DC
voltage) is step 5.
Traverse Waveform
Checking Location: BD board
+
BD board
TP (TE1)
TP (VC)
oscilloscope
0V
B
level: 1.15 
±
 0.5 Vp-p
Center of 
the waveform
A (DC 
voltage)
0V
Tracking servo
Sled servo
ON
C (DC 
voltage)
Tracking servo
Sled servo
OFF