Skew Adjustment
(Be sure to perform this adjustment when the optical pick-up or a
mechanical part of the optical pick-up has been replaced.)
1. Remove the top plate. (See 3. Disassembly/Top Plate Assembly)
2. Remove the eight screw (+B3X8) of the top plate and remove the
KEY board.
3. Connect the KEY board connector and the DISPLAY board con-
nector.
4. Remove the base unit. (Do not disconnect the connectors.)
(Refer to 3. Disassembly/Base Unit.)
5. Adjust with the unit placed sideways as shown in the figure.
6. Connect and oscilloscope to TP (RF: 1Pin of CN215).
7. While pressing the 
±and ·buttons, press the POWER but-
ton. (The discrete open/close detection is turned OFF.)
8. Set a disk (YEDS-18) and press the 
·button.
9. Rotate the adjustment screw with a Phillips screwdriver and ad-
just so that the oscilloscope waveform becomes clear.
Note: A clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
level : 1.2           Vp-p
VOLT/DIV : 200mV
TIME/DIV : 500ns
+0.25
–0.20
Adjustment
screw
Base unit
KEY BOARD
10.After the adjustment, lock the adjustment screw.
[ SERVO BOARD ] — Conductor Side —
CN514
CN513
(ADJ)
(PLK)
CN515
IC101
CN215
CN210
6      4          1
3      1
(RF)
(FE)
(VC)
(TE)
29 (FEI)
27 (TEI)
1
12
10
2
11
1
Note: Hold the base
unit horizontally.