Read Sony CDP-EX880 / CDP-MS717 / DHC-EX880MD / DHC-MD717 Service Manual online
– 38 –
Pin No.
Pin Name
I/O
Function
39
X1
I
Main system clock input terminal (12.5 MHz)
40
VSS
—
Ground terminal
41
XT2
O
Sub system clock output terminal Not used (open)
42
XT1
I
Sub system clock input terminal Not used (fixed at “L”)
43
RESET
I
System reset signal input from the reset signal generator (IC311) “L”: reset
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
44
BUSCLK
O
Bus data transfer clock signal output for the system control bus
45
BUSBSY
I/O
Busy signal in/out terminal for the system control bus
46
SCOR
I
Subcode sync (S0+S1) detection signal input from the CXD2519Q (IC103) in BD section
47
DQSY
I
Data read enable signal input from the CD text decoder (IC104) in BD section
48
NC
O
Not used (open)
49
JOG0
I
Jog dial pulse (0) input from the rotary encoder (S661) (for SELECTOR)
50
JOG1
I
Jog dial pulse (1) input from the rotary encoder (S661) (for SELECTOR)
51
AVDD
—
Power supply terminal (+5V) (for A/D converter)
52
AVREF0
I
Reference voltage (+5V) input terminal (for A/D converter)
53
KEY0
I
Key input terminal (A/D input) (S611 to S613, S616 and S618)
CD1 to CD3, REPEAT, CLEAR keys input
CD1 to CD3, REPEAT, CLEAR keys input
54
KEY1
I
Key input terminal (A/D input) (S621 to S623, S626 to S628)
§ (CD1 to CD3), MENU/NO, ENTER/YES, DISC SKIP keys input
§ (CD1 to CD3), MENU/NO, ENTER/YES, DISC SKIP keys input
55
KEY2
I
Key input terminal (A/D input) (S631 to S638)
fl, p, 0, ), DISPLAY, CONTINUE, SHUFFLE, PROGRAM keys input
fl, p, 0, ), DISPLAY, CONTINUE, SHUFFLE, PROGRAM keys input
56
SELECT0
(CDTEXT)
I
Input terminal for the Japanese letter in function setting
“L”: input possible (fixed at “H” in this set)
“L”: input possible (fixed at “H” in this set)
57
SELECT1
(MECHA MODEL)
I
Input terminal for the separate/complete type setting of CD section and other sections
“L”: separate type, “H”: complete type (fixed at “L” in this set)
“L”: separate type, “H”: complete type (fixed at “L” in this set)
58
DISC SNS
I
Detection input from the disc in detect sensor (Q501) “H”: disc in
59
MID SNS
I
Detection input from the disc tray close detect sensor (IC501) “H”: disc tray is closed
60
(GND)
I
Not used (fixed at “L”)
61
AVSS
—
Ground terminal (for A/D converter)
62
TEST
I
Input terminal for the test (fixed at “L” in this set)
63
NC
O
Not used (open)
64
AVREF1
I
Reference voltage (+5V) input terminal (for D/A converter)
65
SRDT
I
Serial data input from the CD text decoder (IC104) in BD section
66
NC
O
Not used (open)
67
SCLK
O
Serial data transfer clock signal output to the CD text decoder (IC104) in BD section
68
SUBQ
I
Subcode Q data input from the CXD2519Q (IC103) in BD section
69
NC
O
Not used (open)
70
SQCLK
O
Subcode Q data reading clock signal output to the CXD2519Q (IC103) in BD section
71
XMODE
O
Reset/power down mode setting signal output to the CD text decoder (IC104) in BD section
72
SENSE2
I
Internal status monitor input from the CXA1992AR (IC101) in BD section
73
SENSE
I
Internal status monitor input from the CXD2519Q (IC103) in BD section
74
DRV DAT
O
Serial data output to the fluorescent indicator tube driver (IC601) and LED driver (IC602)
75
DRV CLK
O
Serial data transfer clock signal output to the fluorescent indicator tube driver (IC601) and LED
driver (IC602)
driver (IC602)
76 to 83
A0 to A7
O
Address signal output to the S-RAM (IC315)
84 to 91
D0 to D7
I/O
Two-way data bus with the S-RAM (IC315)
92 to 98
A8 to A14
O
Address signal output to the S-RAM (IC315)
99
NC
O
Not used (open)
100
VSS
—
Ground terminal
Click on the first or last page to see other CDP-EX880 / CDP-MS717 / DHC-EX880MD / DHC-MD717 service manuals if exist.