RF PLL Free-run Frequency Check
Procedure :
1.
Connect frequency counter to test point (PLCK) with lead wire.
2.
Turned Power switch on.
3.
Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
Adjustment Location :
[ BD BOARD ] — Conductor Side —
[ MAIN BOARD ] — Conductor Side —
(PLCK)
(RF)
(VC)
(TE)
(FE)
(FEI)
IC103
1
20
11
10
IC101
— 9 —
— 20 —
40
41
25
24
1
80
65
64
IC302
TP1
(ADJ)
frequency counter
BD board
TP (PLCK)
Page of 20