HCD-IS1000/IT1000/IT1000ES
19
SECTION 4
TEST MODE
1. TEST MODES OTHER THAN THE TEST MENU
These are executable test mode even if not entering the test menu.
These are executable test mode even if not entering the test menu.
1-1. AM Step Change
(Except IT1000: AEP, Russian, UK and Saudi Arabia
models)
models)
The step interval of AM channels can be toggled between 9 kHz
and 10 kHz.
Procedure:
1. Press the [
and 10 kHz.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Touch the [FUNCTION] sensor to select the “AM”.
3. Touch the [
3. Touch the [
N
] and [FUNCTION] sensors simultaneously and
hold down (around 5 seconds).
4. The message “AM 9k STEP” or “AM 10k STEP” appears
on the fluorescent indicator tube, and the AM channel step is
changed.
changed.
1-2. Disc Tray Lock
This mode let you lock the disc tray. When this mode is activated,
the disc will not eject when the [
This mode let you lock the disc tray. When this mode is activated,
the disc will not eject when the [
Z
] sensor is touched. The message
“LOCKED” will be displayed on the fluorescent indicator tube.
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Touch the [FUNCTION] sensor to select the “BD/DVD”.
3. Touch the [
3. Touch the [
x
] and [
Z
] sensors simultaneously and hold down
until “LOCKED” or “UNLOCKED” displayed on the fluores-
cent indicator tube (around 5 seconds).
cent indicator tube (around 5 seconds).
1-3. Color System Change
(IS1000: Saudi Arabia, Singapore/IT1000: Austra-
lian, Saudi Arabia and Singapore models)
lian, Saudi Arabia and Singapore models)
This mode let you change the color system of the video output
from PAL to NTSC or vice versa.
Procedure:
1. Press the [
from PAL to NTSC or vice versa.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Touch the [
x
] and [VOLUME +] sensors simultaneously and
hold down (around 5 seconds).
3. The color system is changed.
2. TEST MODES IN THE TEST MENU
These are the test modes done in the test menu.
These are the test modes done in the test menu.
Setting method of the test menu:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press three button in order of the [CLEAR]
→ [3] → [0] →
[1]
→ [0] → [ANGLE] on the remote commander. (Make the
interval when each button is pressed within two seconds)
3. The message “TEST MENU” appears on the fluorescent indi-
cator tube and enter the test menu.
2-1. Panel Test
Procedure:
1. Enter the test menu.
2. Press the [
Procedure:
1. Enter the test menu.
2. Press the [
M
]/[
m
] buttons on the remote commander to select
the “PANEL TEST”, and press the [3] button on the remote
commander.
commander.
3. LEDs and all segments in fl uorescent indicator tube are lighted
up. And half segments in fl uorescent indicator tube are lighted
up, others half segments in fl uorescent indicator tube are light-
ed up, then LEDs and all segments in fl uorescent indicator tube
are lighted up. This operation is repeated.
up, others half segments in fl uorescent indicator tube are light-
ed up, then LEDs and all segments in fl uorescent indicator tube
are lighted up. This operation is repeated.
4. When all segments in fl uorescent indicator tube are lighted up
in the state of step 3, press the [VOLUME +] button on the
remote commander and model information is displayed on the
fl uorescent indicator tube.
remote commander and model information is displayed on the
fl uorescent indicator tube.
Each time the [VOLUME +] button on the remote commander
is pressed, the display changes from destination information,
MC version, SYS version, UI version, DVD version, ST ver-
sion, TA version, DSP version, TM version, CLA version, CEC
version, SAIR version, HDMI version, DSP f version in this
order, and returns to the model information display.
is pressed, the display changes from destination information,
MC version, SYS version, UI version, DVD version, ST ver-
sion, TA version, DSP version, TM version, CLA version, CEC
version, SAIR version, HDMI version, DSP f version in this
order, and returns to the model information display.
Each time the [VOLUME –] button on the remote commander
is pressed, the version and date are switched.
is pressed, the version and date are switched.
5. In the state of step 3, press the [FUNCTION] button on the
remote commander and “K 0” is displayed on the fluorescent
indicator tube.
indicator tube.
“K 0” value increases whenever a button on the set is pressed
or a sensor is touched. However, once a button has been
pressed, it is no longed taken into account.
or a sensor is touched. However, once a button has been
pressed, it is no longed taken into account.
All buttons on the set are pressed and all sensors are touched,
“OK” and “K 7” are alternately displayed on the fluorescent
indicator tube.
“OK” and “K 7” are alternately displayed on the fluorescent
indicator tube.
6. To release from this mode, press the [
?/1
] button.
2-2. AMP Test
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the set to
the customers.
Procedure:
1. Enter the test menu.
2. Press the [
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the set to
the customers.
Procedure:
1. Enter the test menu.
2. Press the [
M
]/[
m
] buttons on the remote commander to select
the “AMP TEST”, and press the [3] button on the remote
commander.
commander.
3. The message “MEASURE” appears on the fluorescent indica-
tor tube and enter the AMP test mode.
4. Press the [SUBTITLE] button on the remote commander,
the fl uorescent indicator tube and thus the VACS on/off are
changed.
changed.
5. To release from this mode, press the [
?/1
] button.
2-3. Cold Reset
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the set to
the customers.
Procedure:
1. Enter the test menu.
2. Press the [
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the set to
the customers.
Procedure:
1. Enter the test menu.
2. Press the [
M
]/[
m
] buttons on the remote commander to select
the “COLD RESET”, and press the [3] button on the remote
commander.
commander.
3. The message “COLD RESET” appears on the fluorescent indi-
cator tube, then becomes standby states.
2-4. BD Service
This mode describes details in “3. BD SERVICE MODE” (page
20).
This mode describes details in “3. BD SERVICE MODE” (page
20).
2-5. Tuner Factory Preset
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-6. Digital Media Port Test
Procedure:
1. Connect the DMPORT check jig (Part No. J-2501-309-A) with
Procedure:
1. Connect the DMPORT check jig (Part No. J-2501-309-A) with
the DMPORT jack (CN1101) on the AV01 board.
2. Press the [
?/1
] button on turn the power on.
3. Confi rm that both LEDs of the DMPORT check jig lights.
(Confi rmation the power supply line)
4. Press the [FUNCTION] button on the remote commander to
(Confi rmation the power supply line)
4. Press the [FUNCTION] button on the remote commander to
select the “DMPORT”.
Ver. 1.1