AVD-K800P, HT-C800DP - Sony Audio Service Manual (repair manual). Page 22

Read Sony AVD-K800P / HT-C800DP Service Manual online

22
AVD-K800P
2-7.  Disc Check Memory
Disc Check Memory
 1. SL Disc check
 2. SL Disc check
 3. SL Disc check
Exit: RETURN
On this screen, measure the mirror time of chucked disc, and write
to the EEPROM.
2-8.  Error Rate Display
Error Rate Display
ERR
Address
C1 Err
Now xxxxxxxx xxxxxxxx
Max xxxxxxxx xxxxxxxx
Avg xxxxxxxx
C2 Err
Now xxxxxxxx xxxxxxxx
Max xxxxxxxx xxxxxxxx
Avg xxxxxxxx
 Start: ENTER
Stop: Return
On this screen, measure and display the error rate.
3.
MECHA AGING
On the Test Mode Menu screen, selecting 
[3]
 executes the aging of
the mechanism deck.
### Aging Test MENU ###
**
 Pls use over 40min. CD 
**
Operation Menu
1. Open/Close Test
Exit: RETURN
1)
On the Aging Test MENU screen, press the 
[1]
  key  on the
remote commander to display the Open/Close Test screen.
2)
Insert discs and press the 
[ENTER]
  key on the remote
commander.
3)
It starts the aging.
During aging, the disc number, operating status and repeat cycle
are displayed. Aging can be aborted at any time by pressing
the
x
key. After the operation is stopped, press the
x
key or
[RETURN]
 key aging to return to the Aging Test MENU.
4.
EMERGENCY  HISTORY
On the Test Mode Menu screen, selecting 
[4]
  displays the
information such as servo emergency history.
The history information from last 1 up to 10 can be scrolled with
the O key or o key. Also, specific information can be displayed
by directly entering that number with ten keys.
### EMG. History ###
  Laser Hours
CD
xxxxhxxm
DVD
xxxxhxxm
a.
bb xx xx xx  xx xx xx xx
xx xx xx xx  xx xx xx xx
a.
bb xx xx xx  xx xx xx xx
xx xx xx xx  xx xx xx xx
   Select:1-9
Scroll:UP/DOWN
  (1.Latest EMG.)
Exit: RETURN
xxxxhxxm : The laser on total hours. Data below minutes are
omitted.
a.
: Error number.
bb
: Error code.
xx
: Not used.
• Clearing History Information
Clearing laser hours:
Press the 
[DVD DISPLAY]
 and 
[CLEAR]
 keys in this order.
Then both CD and DVD data are cleared.
Clearing emergency history:
Press the 
[DVD TOP MENU]
 and 
[CLEAR]
 keys in this order.
Initializing set up data:
Press 
[DVD MENU]
 and 
[CLEAR]
 keys in this order.
The data have been initialized when “Set Up Initialized”
message is displayed. The EMG. History screen will be restored
soon.
Page of 92
Display

Click on the first or last page to see other AVD-K800P / HT-C800DP service manuals if exist.