VC-MH705HM/LM
VC-MH815HM/LM,MH85HM
VC-MH715HM,MH835HM
4. Jumper setting of JP0 to JP39 in hexadecimal notation and REC current setting.
d. Example: 
c. The jumper setting in hexadecimal notation and REC current setting will be displayed on the 
    television screen (upper left). 
a. Check the power on. (Power is ON)
b. Make short circuit test point(TP801) and hold the point.
    Be sure that all the LCD display light up into the TEST mode.
YC  44220707 
VM  F8F9
NOR--
If the jumper setting is set as step 1-d, it will be displayed on television screen
like the example above.
5. Finally release the test point to return to normal screen (E-E mode).
YC   4 4   2 2   0 7   0 7
     V
  V      V
     V
SP LP
SP
EP
 
PAL
NTSC 
     V
     V
JP  003400C010
Page of 3