VC-ME80HM. Service manual front cover to page 56 - Sharp VCR Service Manual (repair manual). Page 52

Read Sharp VC-ME80HM Service Manual online

52
VC-ME80GM
VC-ME80HM
2. Memory recording preset level reprogramming.
1. Similarly to the above step 1-1  and 2 the same operate.
2. Using the CHANNEL (
'
) AND (
"
) buttons, select the right function numbers continued from recording preset
number as has been JP0 to JP39, which appear in the fluorescent display tube, referring to the E
2
PROM map.
3. Press the STOP or REW button on the remote control unit.
By doing, recording level preset number selected by turn from the ten keys on the remote control unit, which appear
in the fluorescent display tube referring to the E
2
PROM map.
4. Example :
System
p : PAL
n : NTSC        
                    
  Tape speed
LP or EPor SP p or n
         
                   
         
Chrominance preset number. (from "0" to "7")                    
        
Luminance preset number. (from "0" to "7")                    
3. Finally make for a moment short-circuit test point(P812), both located at the front side on the main PWB to clear the
TEST mode.
Page of 56