VC-M305HM (serv.man7). Electrical adjustments - Sharp VCR Service Manual (repair manual). Page 4

Read Sharp VC-M305HM (serv.man7) Service Manual online

30
VC-M305HM/LM
VC-M315HM/LM
Mode
EE
ADJUSTMENT OF Receive Image CH
Confirm that there is no noise and beat in the receiving strenght
and weakness electrics signal.
Measuring
instrument
Mode
Cassette
Oscilloscope
Playback
Self-recorded/Playback tape
Test point
VIDEO OUT port
(75
 terminal)
Specification
Check place 1.
(1
±
0.2Vp-p)
VIDEO
Colour Bar
ADJUSTMENT OF PB Level Confirmation
1.0Vp-p
Measure the picture out-
put port using the 75
 ter-
minal Oscilloscope and
confirm the diagram same
as the left diagram.
~
V:200mV/div
H:20
µ
sec/div
Measuring
instrument
Mode
Cassette
Oscilloscope
Recorded/Playback
Self-recorded/Playback tape
Test point
VIDEO OUT
VIDEO
mono-sco
ADJUSTMENT OF S-PICTURE Confirmation
Receive the mono-sco.
Confirmation : make sure no black split at the mono-sco
picture during the self-Rec PB when the S-PICTURE is
ON with the S-PICTURE ON/OFF,make sure the picture
level at the wedge part is change.
(S-PICTURE ON - about 260 line)
(S-PICTURE OFF about 240 line)
Measuring
instrument
Mode
Digital Voltmeter
EE
Specification
2.5
±
0.5V
TUNER/IF  Circuit ADJUSTMENT
ADJUSTMENT OF AFT Adjustment
Confirmation(except France)
Test point
TU101 pin23
E-12ch, Input level 70dB
µ
While selecting channel input TEST MODE(press once
on TEST KEY R/C) and select E-12ch.
(Just Tuning)
Adjustment
ADJUSTMENT OF AFT Adjustment
Confirmation(France)
F-10ch, Input level 70dB
µ
While selecting channel input TEST MODE(press once
on TEST KEY R/C) and select F-10ch.
(Just Tuning)
F-4ch, Input level 70dB
µ
While selecting channel input TEST MODE(press once
on TEST KEY R/C) and select F-4ch.
(Just Tuning)
HM
I40ch
LM
I-Jch
Measuring
instrument
Mode
Digital Voltmeter
EE
Specification
2.5
±
0.5V
Test point
TU101 pin23
Page of 6