VC-M303 (serv.man9). Electrical Trouble Shooting - Sharp VCR Service Manual (repair manual). Page 10

Read Sharp VC-M303 (serv.man9) Service Manual online

47
2. Memory recording preset level reprogramming.
1. Similarly to the above step 1-1  and 2 the same operate.
2. Using the CHANNEL (+) AND (-) buttons,  select the right function numbers continued from recording preset number
as has been  JP0~J39, which appear in the fluorescent display tube, referring to the E
2
PROM map.
3. Press the STOP or REW button on the remote control unit.
By doing, recording level preset number selected by turn from the ten keys on the remote control unit, which appear
in the fluorescent display tube referring to the E
2
PROM map.
4. Example :
System
n : NTSC                    
p : PAL                    
  Tape speed
LP or EP
n
         
                   
        
Chrominance preset number. (from "0" to "7")                    
        
Luminance preset number. (from "0" to "7")                    
3. Finally make for a moment short-circuit test point(P802), both located at the front side on the main PWB to clear the
TEST mode.
Page of 11
Display

Click on the first or last page to see other VC-M303 (serv.man9) service manuals if exist.