VC-M21HM (serv.man14). Counter measure for failure of Q901 - Sharp VCR Technical Bulletin (repair manual)

vc-m21hm (serv.man14) technical bulletin
Model
VC-M21HM (serv.man14)
Pages
1 Few pages! See other manuals at the bottom of the first or last page.
Size
10.63 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
VCR / Counter measure for failure of Q901
File
vc-m21hm-sm14.pdf
Date

Read Sharp VC-M21HM (serv.man14) Technical Bulletin online

Sharp Electronics (UK) Ltd Technical Support Group
Originator 
$Y:
$Y:
 Supervisor 
3*-
3*-
  Approval Date  20/05/96   TB9604807
VCR960901
Issue :
20/05/96
Classification : 
Routine
VIDEO TECHNICAL BULLETIN
Page 1 of 1
MODELS
VCM20HM
VCM201HM
VCMH60HM
VCM41HM
VCM21HM
VCM401HM
VCM202HM
REASON
Due to power fluctuations in excess of the designed operating range of the power
supply circuit, Q901 can over heat.  This may also cause the surge limiter
resistor, R904, to also fail.
ACTION
From March 1996 a heat sink has been added to Q901.  If this has not been fitted
and Q901 has failed, fit heat sink using the part number given below.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
-
Heat Sink
PRDAF1065UMFW
AB
Display

Download Sharp VC-M21HM (serv.man14) Technical Bulletin

Here you can read online and download Sharp VC-M21HM (serv.man14) Technical Bulletin in PDF. VC-M21HM (serv.man14) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp VC-M21HM (serv.man14) VCR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.