VC-M201HM (serv.man2). Counter measure for no output from the RF modulator - Sharp VCR Technical Bulletin (repair manual)

vc-m201hm (serv.man2) technical bulletin
Model
VC-M201HM (serv.man2)
Pages
1 Few pages! See other manuals at the bottom of the first or last page.
Size
6.69 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
VCR / Counter measure for no output from the RF modulator
File
vc-m201hm-sm2.pdf
Date

Read Sharp VC-M201HM (serv.man2) Technical Bulletin online

Sharp Electronics (UK) Limited
Originator AvW   Supervisor                        Approval Date    /   /     Reference PJVCM20RF
Revision   
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
VCR960902
Month of Issue:
        Classification: Routine
VIDEO TECHNICAL BULLETIN
Page 1 of 1
MODELS
VCM20HM
VCM201HM
SYMPTOM No RF output from modulator.
CAUSE
RF turned off by software.
ACTION
To turn RF back on, follow the procedure outlined below.
1.  Press the mode button ( located to the left of the shuttle control ) for about two
seconds.  The VCR's display will indicate 'AUTO CL'.
2.  Press the play button and the display will change to 'OFF:RF'.
3.  Press channel +.  The display will now change to 'ON:RF'.
4.  Press the mode button to return to the normal mode.
Please note that these instructions are given on page 6 of the instruction booklet.
Display

Download Sharp VC-M201HM (serv.man2) Technical Bulletin

Here you can read online and download Sharp VC-M201HM (serv.man2) Technical Bulletin in PDF. VC-M201HM (serv.man2) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp VC-M201HM (serv.man2) VCR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.