Read Sharp VC-A140HM (serv.man14) Technical Bulletin online
VCR2000 05 01
Month of Issue:
May 2000
Classification:
White
VIDEO TECHNICAL BULLETIN
Page 1 of 1
Sharp Electronics (UK) Limited
Reference AVW19052000-4
Revision 1
White Carry out as required
Yellow Carry out as required and whenever the unit comes in for service
Red Carry out on all units
MODELS
VCA100H
VCA105H
VCA111H
VCA113H
VCA140H
VCA170H
VCA131H
VCA501H
VCA5011HM
VCA502H
VCD801H
VCT310H
VCT510H
VCT72HM
SYMPTOM After about ten minutes in either the record or playback modes, the capstan motor
slows down or stops, resulting in the unit reverting to the standby mode.
CAUSE
Lack of lubrication on the capstan motor bearing leads to overheating the drive IC,
which then shuts down the unit.
ACTION
Remove the capstan shaft from the bearing and lightly lubricate.
If the above action does not cure the problem, the capstan motor will have to be
replaced.