<Commands for ID control>
The command examples shown on this page assume the following connection and ID number set
up.
PC
ID number: 1
ID number: 2
ID number: 3
ID number: 4
IDST······A monitor receiving this command sets its own ID number in the parameter field.
Example:
IDST0001
OK
001
 ←The ID number of this monitor is set to 1.
Note
After linking monitors, you can automatically assign ID numbers by using the IDST command with
the Repeater control (see “Repeater control” on page 40).
PC
Set 1
Set 2
Set 3
Set 4
[Example]
If you connect monitors as shown above, and use the command “IDST001+”, ID numbers
will be set automatically, as shown below.
PC
ID number: 1
ID number: 2
ID number: 3
ID number: 4
[Example]
IDST001+
←ID setting command with repeater control
WAIT
OK
001
←ID = “OK” response from ID number=1
OK
002
←ID = “OK” response from ID number=2
OK
003
←ID = “OK” response from ID number=3
OK
004
←ID = “OK” response from ID number=4 (End)