LC-70LE741E (serv.man11). Troubleshooting Table - Sharp TV Service Manual (repair manual). Page 63

Read Sharp LC-70LE741E (serv.man11) Service Manual online

LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E
6 – 63
4) Communication failure details (Low-speed blinking: Flashes 3 times + High-speed blinking)
5) Other failure details (Low-speed blinking: Flashes 4 times + High-speed blinking)
Error type
Expression of Central Icon LED
Note: Basically, debug print logs are analyzed or 
           communication logs are analyzed by a bus monitor.
Initial communication 
reception failure
Flashes once
(High speed)
H: ON
L: OFF
Initial communication from the main CPU is not received.
(Request for the monitor model No. is not received.)
→ Communication line failure or main CPU start-up failure.
Start-up confirmation 
reception failure
Flashes twice 
(High speed)
H: ON
L: OFF
Start-up reason confirmation from the main CPU cannot be 
received.
(Startup communication until start-up reason notification command 
is not received.)
→ Main CPU start-up failure or monitor microprocessor reception 
     failure.
Regular communica-
tion failure
Flashes 3 times
(High speed)
H: ON
L: OFF
Regular communication that is performed at 1 second intervals in 
the normal operation is interrupted.
→ Main CPU operation failure or monitor microprocessor 
     reception failure.
Other communica-
tion failure
Flashes 5 times
(High speed) 
H: ON
L: OFF
When a request (PM_REQ=H) is sent from the main microproces-
sor, the request command is not output from the main CPU, etc.
→ Main CPU operation failure or monitor microprocessor 
     reception failure.
Error type
Expression of Central Icon LED
Monitor temperature 
failure
Flashes once 
(High speed)
H: ON
L: OFF
If the panel temperature is 60
°C or more for 15s or more in a row, 
CAUTION appears on the OSD (flashes in red in the lower right 
screen).
If the panel temperature is 60
°C or more for 25s or more in a row, 
error standby is activated.
(MONITOR MAX TEMP on page (12/20) of the adjustment pro-
cess: Change AD value for temperature failure): Thermistor
Main failure
Flashes 3 times 
(High speed)
H: ON
L: OFF
Main microprocessor detection error (CPU temperature error, etc.)
Details are displayed on page (1/20) of the adjustment process for 
the main microprocessor.
Page of 63
Display

Download Sharp LC-70LE741E (serv.man11) Service Manual (Repair Manual)