Read Sharp LC-60LE831E (serv.man20) Technical Bulletin online
LCD 2012 06 01
Date of Issue:
15
th
June 2012
Classification:
Yellow
LCD TELEVISION TECHNICAL BULLETIN
Page 1 of 1
Sharp Electronics (UK) Limited
Reference – LCEU253
Revision - 1
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
Red – Carry out on all units
MODELS
LC60LE831E
SYMPTOM Dead.
CAUSE
Mains input fuse blown.
ACTION
Please check that the mains switch wiring is correctly positioned in all cases as there
is a possibility that the cable could become trapped between the cabinet back and
LCD panel if wall mounted.
is a possibility that the cable could become trapped between the cabinet back and
LCD panel if wall mounted.
See below for correct position of the cables and relocate if there is a difference.
Figure 1: Re-position tape numbers 4,6,8 to raise cables above Lower L.H. VESA fixing point.