LC-60LE636E (serv.man8). Major IC Informations - Sharp TV Service Manual (repair manual). Page 8

Read Sharp LC-60LE636E (serv.man8) Service Manual online

LC-60LE635E/636E/638E (1st Edition)
6 – 8
Table 1. Concrete flashing pattern
*2: It depends on the system. The power supply error suitable for the product is defined.
*3: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
*4: If the boot section is abnormal, there is no flashing (flashing disabled).
MONITOR ERR STBY table
Item
Expression for a rough content
Expression for Details
Cause
low-speed
blinking
high-speed 
blinking
low-speed
blinking
high-speed 
blinking
Lamp system failure  Flashes once 
Flashes once 
Flashes once 
Lamp error
Power PWB failure
Flashes twice 
Flashes twice 
Flashes once 
Power Error 1 AC_DET error (*2) 
(Power failure, etc.)
Flashes twice 
Power Error 2 UR+13.5V error (*2) 
Flashes 3 times 
Power Error 3 D3.3V error (*2) 
Flashes 5 times 
Panel power supply error
Main PWB failure 
Flashes 3 times 
Flashes 3 times 
Flashes once 
Initial communication error
(Communication Flashes 
twice 
Start-up confirmation communication error
failure, etc.) 
Flashes 3 times 
Regular communication error
Flashes 5 times 
Other communication error
Others 
Flashes 4 times 
Flashes 4 times 
Flashes once 
Temperature error
Flashes twice 
Sync error
Flashes 3 times 
Notification from the main microprocessor 
(*3)
Upgrade executing 
smoothness 
changes. 
Version upgrading
Upgrade completion
a staircase 
pattern. 
Version upgrade succeeded
Upgrade failed 
Flashing
(Continuous)
Version upgrade failed
ROM data failure 
Flashing
(Continuous)
Start-up after failing version upgrade (*4)
Outline: Communication/Power failure detected by the monitor microprocessor (IC2001) is stored on EEPROM, states can be confirmed in the 
adjustment process mode.
Location: Page (1/20) of the adjustment process mode: MONITOR ERR CAUSE “0” if there is no error. It is cleared to 0 on the page (2/20) of the 
adjustment process mode.
Display Error 
description
02
Start-up communication error 2 
Initial communication from the main CPU is not received.
03
Start-up communication error 3 
Only the initial communication is received.
04
Start-up communication error 4
Until panel information request reception
05
Start-up communication error 5
Until initialization completion reception
06
Start-up communication error 6
Until version notification transmission
07
Start-up communication error 7
Until start-up information notification transmission
08
Start-up communication error 8
Until start-up information response reception
09
Start-up communication error 9
Until time-out setting reception
0A
Communication error A 
REQ time-out
0B
Communication error B 
Restart time-out during the beginning of time acquisition start-up
0C
Communication error C 
Ending sequence time-out
0D
Communication error D 
Preset start-up time-out during completion
0E
Communication error E 
Download start-up time-out
0F
Communication error F 
Time acquisition time-out
11
 Communication error H
Regular communication time-out
16
Panel-related error 
Lamp failure
1A
Other error 2 
Monitor temperature failure
1D
Power supply error 1 
PS_ON (AC_DET) failure
1E
Power supply error 2 
D_POW (DET_13V) failure
1F
Power supply error 3 
D_POW (DET_D3V3) failure
21
Power supply error 5 
Panel power failure
23
Other error 3 
Error standby request from the main CPU
Page of 10
Display

Click on the first or last page to see other LC-60LE636E (serv.man8) service manuals if exist.